Related Experiment Video
Updated: Jul 5, 2026

2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
[Case of complete denture using piezography]
1Division of Oromaxillofacial Regeneration, Osaka University Graduate School of Dentistry. moto1113@aol.com
Patient:
A 69-years-old edentulous male patient visited with a chief complaint of repeated fracture of a lower complete denture. A new denture was fabricated to improve the denture base rigidity and to modify the shape of the polished surface and position of the artificial teeth arrangement.
Discussion:
It seemed that the lower complete denture was broken repeatedly because the thickness in the central part was insubstantial there was not a reinforcement metal structure, and possibly the occlusal force was strong. By Piezography method, we attempted to assemble the components requisite to improve strength including reinforcement of the metal structure.
Conclusion:
In this case, a lower complete denture was successfully produced with high rigidity that might not obstruct the denture stability, by applying Piezography.
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography