Related Experiment Video
Updated: Jul 5, 2026

A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps
Published on: August 5, 2015
Analysis of the causes of pump failure and differences of failure characteristics
H Korving1, E C Ottenhoff, H Korving
1Witteveen + Bos Consulting Engineers, PO Box 233, 7400 AE, Deventer, The Netherlands. j.korving@witteveenbos.nl
Abstract:
It is generally accepted that sewage pumping stations are directly responsible for affecting sewer system performance in terms of combined sewer overflows and flooding. However, the specific causes of pump failure are unknown. This paper presents the analysis of pump failure data provided by four sewer management authorities in The Netherlands. Pump failures have been studied accounting for the nature of failures, operation and maintenance procedures of the management authority, ageing of the pumps and changes in the environment of pumps. Pumps have been clustered on the basis of specific characteristics of their 'environment', including pump age, operating time, pump capacity and degree of pollution of the sewage. The analysis shows that the well known 'bathtub' type failure rate curve can describe failures of sewage pumps. The impact of the degree of pollution of the sewage, however, is less clear. Operating time and total pumping capacity show no correlation with failure rate. Consequently, further research using data mining techniques is needed to separate the impact of the different aspects of the environment of a pump.
Related Concept Videos
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Fatigue
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Typical Model Studies