Abstract:
A sensitive, precise, and specific gas chromatographic (GC) method was developed for the analysis of capsaicin in Gochujang and validated by comparing with a column high-performance liquid chromatographic (HPLC) method (AOAC 995.03). The method validation parameters yielded good results, including linearity, precision, accuracy, and recovery. The GC separation was performed on a (5% phenyl)-methylpolysiloxane column [length 30 m, internal diameter (id) 250 microm, film thickness 0.25 microm] followed by flame ionization detection. The conditions of temperature programming were initially 220 degrees C for 1 min, ramp at 5 degrees C/min to 270 degrees C, and hold for 10 min. The recovery of capsaicin in Gochujang was more than 92%, and the detection limit and lower determination limit of the GC analysis were 1.0 and 5.0 microg/g, respectively. The calibration graph for capsaicin was linear from 1 to 250 microg/mL for GC and 0.5 to 50 microg/mL for HPLC. The interday and intraday precisions (relative standard deviations) were <4.02%.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
10:09A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC)
Published on: March 15, 2017
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...