Multivariate optimization of a GC-MS method for determination of sixteen priority polycyclic aromatic hydrocarbons in
Wilson A Lopes1, Gisele O da Rocha, Pedro A de P Pereira
1Instituto de Química, Universidade Federal da Bahia, Campus de Ondina, Salvador-BA, Brazil.
Abstract:
This paper describes the development and optimization, by using multivariate analysis, of a GC-MS-SIM method for evaluation of the 16 polyaromatic hydrocarbons considered as priority pollutants in atmospheric particulate material by the US EPA. In order to assure an adequate separation in the shortest analysis time, a multivariate design was used to set the conditions of the oven temperature program. The optimization process was carried out using factorial fractional design and Box-Behnken design. The following factors were evaluated: initial temperature, temperature rate #1, intermediary temperature, temperature rate #2, and final temperature. The optimized conditions were set at: 70 degrees C (2 min) --> 200 degrees C (30 degrees C/min, 5 min) --> 300 degrees C (5 degrees C/min, 1.67 min). Moreover, we have also optimized the injector temperature as 310 degrees C and sampling time as 0.8 min. The total analysis time was 33 min. Validation of GC-MS-SIM yielded satisfactory results for repetitivity of the detector response and retention times, and linearity of calibration curves. LOD were established as 0.13-0.34 ng/mL (peak area) and 0.18-0.72 ng/mL (peak height). The method has been shown to be appropriate for the analysis of samples of atmospheric particulate material and/or other environmental matrices.
More Related Videos
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...