Related Experiment Video
Updated: Jul 5, 2026

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Radiation safety for the NOMAD portable X-ray system in a temporary morgue setting
Kenneth P Hermsen1, Stanley S Jaeger, Mackenzie A Jaeger
1Creighton University Medical Center School of Dentistry, Omaha, NE 68178, USA. kennethhermsen@creighton.edu
Abstract:
The purpose of this study was to determine the radiation levels resulting from leakage and scatter encountered by the forensic dental personnel using the Nomad at St. Gabriel, LA, following Hurricane Katrina. Using a Keithley Radiation Survey Meter and Lucite head phantom, radiation levels were measured at various distances and angles from the Nomad corresponding to the positions occupied by the dental personnel at St. Gabriel. The measurements were used to approximate the maximum total radiation dose from the Nomad to each team member for a 2- and a 4-week deployment. The results show that the maximum scatter radiation dose to any team member was 4.4 microR per X-ray or 0.253 millisieverts (mSv) for a 2-week deployment and 0.506 mSv for a 4-week deployment. Therefore, the leakage and scatter radiation dose from the Nomad was insignificant compared with established radiation safety guidelines of 50 mSv per year for all team members.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
X-ray Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...