Two-dimensional strain to assess regional left and right ventricular longitudinal function in 100 normal foetuses
Giovanni Di Salvo1, Maria Giovanna Russo, Dario Paladini
1Pediatric Cardiology Department, Second University of Naples, INBB Research Unit, Via Omodeo 45, Naples 80128, Italy.
Summary
Two-dimensional (2D) strain imaging (2D-S) offers a feasible and reproducible method for assessing fetal heart function. This novel technique overcomes limitations of previous methods, providing accurate strain measurements in developing fetuses.
Area of Science:
- Cardiology
- Fetal Medicine
- Medical Imaging
Background:
- Myocardial velocity measurements lack sensitivity in fetal heart assessments.
- Doppler-derived strain imaging in fetuses has been limited by angle dependency and poor reproducibility.
- Two-dimensional (2D) tissue tracking strain (2D-S) echocardiography offers angle independence and improved reproducibility.
Purpose of the Study:
- To evaluate the feasibility and reproducibility of 2D-S for assessing regional myocardial deformation in the human fetal heart.
- To establish normal ranges for fetal ventricular strain using 2D-S.
- To assess the correlation between fetal age and myocardial strain.
Main Methods:
- 100 normal fetuses (20-32 weeks gestation) underwent 2D-S imaging.
- Left ventricle (LV) and right ventricle (RV) peak myocardial negative strain values were measured.
- Inter- and intra-observer variability was assessed.
Main Results:
- 2D-S data were successfully acquired from all fetuses, with post-processing taking approximately 3 minutes per dataset.
- Peak longitudinal strain values were consistent across ventricular walls (septum, lateral, RV free wall).
- Significant correlation found between gestational age and peak longitudinal strain (P < 0.001).
- Excellent inter-observer (<3%) and intra-observer (<6%) variability for strain measurements.
Conclusions:
- 2D-S is a feasible and reproducible technique for evaluating fetal cardiac function.
- The method is ready for clinical application in assessing regional ventricular function in fetuses.
- 2D-S provides a sensitive tool for non-invasive assessment of myocardial deformation in fetal cardiology.