Myocardial contrast echocardiography in biopsy-proven primary cardiac amyloidosis
Sahar S Abdelmoneim1, Mathieu Bernier, Diego Bellavia
1Mayo Cardiovascular Ultrasound Imaging and Hemodynamic Laboratory, Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
Abstract:
Cardiac vasculature is affected in 88-90% of patients with primary cardiac amyloidosis (CA). Myocardial contrast echocardiography (MCE) relies on the ultrasound detection of microbubble contrast agents that are solely confined to the intravascular space, and are therefore useful in the evaluation of flow in the microvasculature. This is the first case report describing the use of MCE during vasodilator stress to evaluate coronary flow reserve in a patient with biopsy-proven primary CA and angiographically normal coronaries. Qualitative MCE demonstrated delayed replenishment of microbubbles during peak stress; quantitative analysis was consistent with a reduction in total myocardial blood flow and reserve values. Comparative imaging modalities including strain and strain rate imaging, magnetic resonance imaging, and myocardial scintigraphy were suggestive to the diagnosis of CA. In conclusion, MCE is a method for recognition of microvascular dysfunction, and might be considered as a useful tool to augment echocardiographic assessment in the early diagnosis of CA.
Insights
Myocardial contrast echocardiography (MCE) effectively detects microvascular dysfunction in primary cardiac amyloidosis (CA). This ultrasound technique aids in early diagnosis when coronary arteries appear normal.
Area of Science:
- Cardiology
- Medical Imaging
- Echocardiography
Background:
- Primary cardiac amyloidosis (CA) significantly affects cardiac vasculature in most patients.
- Microvascular dysfunction is a key feature in CA, impacting myocardial blood flow.
- Myocardial contrast echocardiography (MCE) visualizes intravascular microbubbles to assess microvascular function.
Observation:
- This case report details the first use of MCE with vasodilator stress in a patient with biopsy-proven primary CA and normal coronary angiograms.
- Qualitative MCE showed delayed microbubble replenishment during peak stress.
- Quantitative MCE revealed reduced total myocardial blood flow and reserve.
Findings:
- MCE identified microvascular dysfunction in a patient with primary CA.
- The technique demonstrated reduced myocardial blood flow and reserve capacity.
- Comparative imaging supported the diagnosis of CA.
Implications:
- MCE is a valuable tool for recognizing microvascular dysfunction in CA.
- This method can augment echocardiographic assessment for early CA diagnosis.
- MCE may improve diagnostic accuracy in challenging CA cases.
Related Concept Videos
Myocarditis II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies
Cardiomyopathy IV: Restrictive Cardiomyopathy
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...

