Related Experiment Video
Updated: Jul 5, 2026

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Client-based adjustments of hearing aid gain: the effect of different control configurations
Wouter A Dreschler1, Gitte Keidser, Elizabeth Convery
1Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. w.a.dreschler@amc.nl
Objectives:
Facilitating the fine-tuning of advanced hearing aids requires information about the acoustic environment. The concept of a "trainable" hearing aid may provide a more direct approach to hearing aid fine-tuning if the aid user is allowed to control the most important fitting parameters in his/her own acoustic environments.
Design:
In a laboratory study, the concept of self-adjustment of the gain-frequency response was tested by 24 hearing aid users using four different controllers with a limited number of control functions. Research questions focused on the reproducibility of the fine-tuned responses, the efficiency of the control configurations, and the effects of the control configuration on the end results of the fine-tuning process.
Results:
The subjects were able to provide systematic and reproducible feedback with respect to their preferences in different acoustic conditions presented audiovisually, achieving an average shortterm test/retest standard deviation value of 2.8 dB. Two of the control configurations, featuring volume/slope and volume/bass/treble keys, were found to be more time-efficient and reliable, and were also preferred by 86% of the subjects. Although the control configuration did not have a strong influence on the end result, the gain-frequency response from which the subjects started their adjustments was found to have a significant effect on their preferred settings.
Conclusions:
Client-based adjustments of hearing aid gain provide a reliable method of individual fine-tuning. The results also showed that a biased correction of amplification is reached via self-adjustment within one session, which reduces the effectiveness of fine-tuning in a traditional clinical setting.
Related Concept Videos
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Gain
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller aligns...
Impedance Combination
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable characteristic of...