Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Masking and Demasking Agents01:19

Masking and Demasking Agents

EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Design and imaging performance of achromatic diffractive-refractive x-ray and gamma-ray Fresnel lenses.

Applied optics·2004
See all related articles

Related Experiment Video

Updated: Jul 5, 2026

Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

Sensitivity of coded mask telescopes.

Gerald K Skinner1

  • 1University of Maryland, College Park, MD 20742, USA. skinner@milkyway.gsfc.nasa.gov

Applied Optics
|May 22, 2008
PubMed
Summary

This study presents general formulas for estimating the sensitivity of coded mask telescopes, addressing limitations of simpler models for x-ray and gamma-ray astronomy. The findings improve accuracy for coded mask imaging systems by accounting for detector resolution and mask design.

Area of Science:

  • Astronomy and Astrophysics
  • Instrumentation and Technology

Background:

  • Simple formulas for coded mask telescope sensitivity have limitations.
  • Complications arise from grid structures, detector resolution, and unmet assumptions.

Purpose of the Study:

  • Derive general expressions for Poisson-noise-limited sensitivity in coded mask telescopes.
  • Provide a framework for calculating sensitivity when simple formulas fail.
  • Optimize coded mask telescope design for improved source location accuracy.

Main Methods:

  • Developed generalized mathematical expressions for sensitivity calculations.
  • Analyzed the impact of detector spatial resolution and mask element size.
  • Focused on clear nomenclature and revealing techniques for analysis.

More Related Videos

Testing Tactile Masking between the Forearms
08:05

Testing Tactile Masking between the Forearms

Published on: February 10, 2016

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Related Experiment Videos

Last Updated: Jul 5, 2026

Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

Testing Tactile Masking between the Forearms
08:05

Testing Tactile Masking between the Forearms

Published on: February 10, 2016

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Main Results:

  • Derived more broadly applicable formulas for coded mask telescope sensitivity.
  • Identified conditions under which simplified formulas are strictly valid.
  • Determined optimal mask element size relative to detector pixels for source location accuracy.

Conclusions:

  • General expressions enhance the accuracy of sensitivity estimations for coded mask telescopes.
  • The study provides a procedure for calculating sensitivity in complex scenarios.
  • Optimized mask element sizing is crucial for precise astronomical source localization.