Related Experiment Video
Updated: Jul 5, 2026

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
Published on: June 12, 2015
Multivariate curve resolution of pH gradient flow injection mixture analysis with correction of the Schlieren effect
Renato L Carneiro1, Jez Willian B Braga, Ronei J Poppi
1Universidade Estadual de Campinas, Instituto de Química, C.P. 6154, CEP, 13084-971, Campinas, SP, Brazil.
Abstract:
Multivariate curve resolution using alternating least squares (MCR-ALS) was used to quantify ascorbic (AA) and acetylsalicylic (ASA) acids in four pharmaceutical samples using a flow injection analysis (FIA) system with pH gradient and a diode array (DAD) spectrometer as a detector. Four different pharmaceutical drugs were analyzed, giving a data array of dimensions 51 x 291 x 61, corresponding respectively to number of samples, FIA times and spectral wavelengths. MCR-ALS was applied to these large data sets using different constraints to have optimal resolution and optimal quantitative estimations of the two analytes (AA and ASA). Since both analytes give an acid-basic pair of species contributing to the UV recorded signal, at least four components sholuld be proposed to model AA and ASA in synthetic mixture samples. Moreover, one additional component was needed to resolve accurately the Schlieren effect and another additional component was also needed to model the presence of possible interferences (like caffeine) in the commercial drugs tablets, giving therefore a total number of 6 independent components needed. The best quantification relative errors were around 2% compared to the reference values obtained by HPLC and by the oxidation-reduction titrimetric method, for ASA and AA respectively. In this work, the application of MCR-ALS allowed for the first time the full resolution of the FIA diffusion profile due to the Schlieren effect as an independent signal contribution, suggesting that the proposed MCR-ALS method allows for its accurate correction in FIA-DAD systems.
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Uniform Depth Channel Flow: Problem Solving
Bernoulli's Equation for Flow Along a Streamline
Relative Velocity in Two Dimensions
Bernoulli's Equation for Flow Normal to a Streamline
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines. However, the...

