Related Experiment Video
Updated: Jul 5, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
A multidisciplinary survey on capillary refill time: Inconsistent performance and interpretation of a common clinical
Anna-Theresa Lobos1, Kusum Menon
1Department of Pediatrics, University of Ottawa, Department of Critical Care, Children's Hospital of Eastern Ontario, Ottawa, Ontario, Canada. alobos@cheo.on.ca
Objective:
Capillary refill time is a common clinical test used in pediatric critical care and emergency medicine. Despite this, we hypothesize that capillary refill time is performed inconsistently and its interpretation by healthcare providers in the acute care setting is variable.
Design:
Multidisciplinary survey.
Setting:
Canadian tertiary care pediatric hospital.
Subjects:
Subjects were 198 pediatric healthcare providers.
Interventions:
A self-administered questionnaire survey was sent to healthcare providers in pediatric and neonatal critical care, emergency medicine, and cardiology.
Measurements And Main Results:
Seventy-eight surveys were returned: 23 of 33 pediatric trainees (70%), 22 of 38 staff physicians (58%), and 33 of 125 nurses (26%). Ninety-five percent of pediatric healthcare providers reported performing capillary refill time on most patients. However, while 90% of nurses and 70% of trainees described performing capillary refill time on every patient, only 18% of staff physicians reported performing capillary refill time routinely on every patient. Although all participants responded that a capillary refill time of >3 secs was abnormal, responders were divided on the definition of normal capillary refill time. While other sites were described, responders most commonly reported performing capillary refill time on a patient's chest. Ninety-six percent of responders agreed that prolonged capillary refill time indicates abnormal perfusion.
Conclusions:
The results of this single-institution survey show that while most nurses and pediatric trainees reported using capillary refill time on every patient as a test for perfusion, only a few staff physicians reported using capillary refill time on every patient. In addition, although this study shows that the majority of survey responders stated that they used capillary refill time frequently, we observed no consistent response in how they performed and interpreted capillary refill time. Given that the use of this simple, noninvasive clinical test is supported by many pediatric organizations and pediatricians, the results of this study emphasize the need to examine why this test is inconsistently performed by healthcare providers so as to ensure its reliable performance in the future.
Related Concept Videos
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation