Related Experiment Video
Updated: Jul 5, 2026

Impacts of Free-falling Spheres on a Deep Liquid Pool with Altered Fluid and Impactor Surface Conditions
Published on: February 17, 2019
Bubble formation after a 20-m dive: deep-stop vs. shallow-stop decompression profiles
Nico A M Schellart1, Jan-Jaap Brandt Corstius, Peter Germonpré
1Department of Medical Physics, Academic Medical Centre, University of Amsterdam, The Netherlands. N.A.Schellart@amc.uva.nl
Objectives:
It is claimed that performing a "deep stop," a stop at about half of maximal diving depth (MDD), can reduce the amount of detectable precordial bubbles after the dive and may thus diminish the risk of decompression sickness. In order to ascertain whether this reduction is caused by the deep stop or by a prolonged decompression time, we wanted to test the "deep stop" theory without increasing the total decompression time. From a modeling point of view, Haldanian theory states that this situation would increase the probability of observable bubbles, because of a longer stay at depth. Under these conditions, we examined whether a "deep-stop dive" (DSD) produces more bubbles or less than a "shallow-stop dive" (SSD).
Methods:
Recreational divers performed either a DSD or a SSD. Both groups were matched biometrically. MDD was 20 msw, bottom time 40 min and total diving time 47 min. In DSD, the "deep" stop (10 msw) replaced 3 min of the 7 min stop at 4 msw of SSD.
Results:
DSD produced significantly more precordial bubbles than SSD after knee bends (P-values ranging from 0.00007 to 0.038).
Discussion:
Our results indicate that at least for the tested dive profile, the higher supersaturations after surfacing overruled any possible beneficial effects of the deep stop on bubble formation. The usefulness of substituting a shallow stop with a deep stop in dives up to 20 msw can be questioned; at the least, more research is needed.
More Related Videos
08:19Induction of Microstreaming by Nonspherical Bubble Oscillations in an Acoustic Levitation System
Published on: May 9, 2021
11:14A Microfluidic System with Surface Patterning for Investigating Cavitation Bubble(s)–Cell Interaction and the Resultant Bioeffects at the Single-cell Level
Published on: January 10, 2017
Related Concept Videos
Excess Pressure Inside a Drop and a Bubble
Buoyancy and Stability for Submerged and Floating Bodies
Buoyancy
To get...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Uniform Depth Channel Flow
Uniform Depth Channel Flow: Problem Solving