Related Experiment Video
Updated: Jul 5, 2026

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Reliability of new pulse CO-oximeter in victims of carbon monoxide poisoning
M Coulange1, A Barthelemy, F Hug
1Réanimation Médicale et Hyperbarie, Hôpital Sainte Marguerite, Marseille, France.
Study Objective:
The purpose of this study was to evaluate the reliability of noninvasive real-time measurement of carboxyhemoglobin (COHb) using a pulse CO-oximeter in victims of carbon monoxide poisoning (COP).
Methods:
During the 7-month study period, pulse CO-oximetry was measured on patients admitted to the emergency department (ED) for suspected COP. Each patient included in the study underwent concomitant assessment of COHb by blood sampling and noninvasive pulse CO-oximetry (SpCO).
Results:
Twelve non-smoker patients were included. Mean age was 40 +/- 17 years. No difference was found between the two COHb assessment techniques (p>0.05). Analysis using the Bland and Altman procedure suggested good alignment of the two techniques with a slight bias (i.e. -1.5%) indicating slight overestimation by the pulse CO-oximeter. Analysis using the Passing and Bablok statistical protocol further documented the reliability of the two methods.
Conclusion:
This study documents the precision of the correlation between readings obtained with the noninvasive pulse CO-oximeter and COHb measurements from blood samples. This preliminary result demonstrates that this simple rapid noninvasive technology could be useful before and after arrival at the ED.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...