Abstract:
To evaluate the effectiveness of contrast-enhanced ultrasound (CEUS) in the diagnosis and characterization of hepatic, renal and splenic traumatic injuries versus conventional ultrasound (US) and multislice computed tomography (MS-CT). Between January 2005 and January 2007, 78 patients (48 males, 30 females, mean age 56 years) with blunt abdominal trauma were examined by conventional US, CEUS and MS-CT. CEUS employed a low-MI technique using 1.2 to 2.4 ml of SonoVue (Bracco, Italy) i.v. and a multifrequency transducer (2-4 MHz, Siemens, Sequoia, Acuson). CT examinations were performed on a 64 detector CT scanner (Somatom Sensation 16 or 64, Siemens Medical Systems, Forchheim, Germany) before and after administration of 120 ml intravenous contrast agent (Solutrast, Bracco, Milan, Italy) followed by 50 ml saline. The presence of hepatic, renal and splenic injuries was analyzed and the conspicuousness of findings was assessed. In 15 of the 78 patients conventional US identified solid organ injuries: 8 hepatic, 2 renal and 5 splenic injuries. CEUS identified 3 more injuries (2 hepatic and 1 splenic) that had been missed by conventional US. CEUS identified traumatic lesions in 18/78 patients. In one of the 18 patients even active bleeding could be identified by CEUS. In CEUS solid organ injuries appeared hypoechoic. MS-CT identified 18 solid organ injuries in 78 patients, corroborating the CEUS results.CEUS greatly improves the visualization and characterization of hepatic, renal and splenic injuries compared to conventional ultrasound and correlates well with MS-CT. The imaging technique detects even minor blood flow and is able to depict vascular structures in detail. At our institution it is used as an additional examination technique which supplements MS-CT in unclear cases. Owing to its bedside availability, CEUS provides a good alternative to MS-CT, especially in patients with contraindications to CT contrast agents (e.g. due to renal failure or severe allergy) and in hemodynamically compromised patients.
Related Concept Videos
Imaging Studies III: Computed Tomography
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT