Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and
João Aris Kouyoumdjian1, Erik V Stålberg
1Faculdade de Medicina de São José do Rio Preto, Department of Neurological Sciences, Neuromuscular Investigation Laboratory, Rua Luiz Antonio Silveira 1661, São Paulo 15025-020, Brazil. jaris@terra.com.br
This study estimated normal jitter in the extensor digitorum communis (EDC) and orbicularis oculi (OOc) muscles using a disposable concentric needle electrode (CNE). Findings establish new reference values for CNE jitter in these muscles.
Area of Science:
- Neurology
- Electromyography
- Clinical Neurophysiology
Background:
- Jitter analysis is crucial for diagnosing neuromuscular disorders.
- Normal jitter values are essential for interpreting abnormal findings.
- Disposable concentric needle electrodes (CNE) offer a practical approach to electrophysiological assessments.
Purpose of the Study:
- To estimate normal jitter values in voluntarily activated extensor digitorum communis (EDC) and orbicularis oculi (OOc) muscles.
- To establish reference ranges for jitter using a disposable concentric needle electrode (CNE).
- To provide practical upper limits for mean consecutive difference (MCD) jitter values in EDC and OOc muscles.
Main Methods:
- Jitter was measured in 67 subjects for EDC and 50 subjects for OOc.
- Disposable concentric needle electrodes (CNE) were used for voluntary muscle activation.
- Jitter values were quantified as the mean consecutive difference (MCD) of 20 potential pairs.
Main Results:
- The mean MCD for EDC jitter was 23.6 ± 3.1 µs (95% CL: 29.7 µs).
- The mean MCD for OOc jitter was 24.7 ± 3.1 µs (95% CL: 31.0 µs).
- Suggested practical limits for EDC were 30 µs (mean MCD) and 42 µs (outliers); for OOc, 31 µs (mean MCD) and 41 µs (outliers).
Conclusions:
- Disposable concentric needle electrodes (CNE) can reliably assess jitter in EDC and OOc muscles.
- The study provides the largest series of CNE jitter values during voluntary activation to date.
- Precautions are necessary when using CNE for jitter assessment to ensure accurate results.