Remaining unreacted methacrylate groups in resin-based composite with respect to sample preparation and storing
Vesna J Miletic1, Ario Santini
1Postgraduate Dental Institute, University of Edinburgh, Edinburgh EH3 9HA, United Kingdom. vesna.miletic@gmail.com
Abstract:
The aim of this study was to measure degree of conversion (DC) of resin-based composites (RBCs) using micro-Raman spectroscopy followed by different sample preparation procedures and storing conditions. Ninety samples of Tetric EvoCeram (Ivoclar Vivadent, Schaan, Liechtenstein) were prepared in standardized molds and cured with a high powered LED light-curing unit, bluephase (Ivoclar Vivadent, Schaan, Liechtenstein) for 20 s. Samples were allocated to eight groups. DC of groups 1 and 2 was recorded without or after polishing. DC in groups 3 and 4 was recorded from vertically sectioned samples versus "split" samples. DC in groups 5-8 was recorded after storing samples at room temperature and humidity, in 90 +/- 2% humidity at 37 +/- 1 degrees C, distilled water at 37 +/- 1 degrees C or buffered incubation medium (BIM) at 37 +/- 1 degrees C for 24 h. Mean values of DC in polished and unpolished samples were 63.6% (+/-3.2%) and 54.7% (+/-5.2%), respectively (p < 0.0001). There was no significant difference in DC after sample-sectioning (p > 0.05). Significantly higher DC values were obtained after storing samples in BIM (76.8% +/- 2.1%) than in distilled water (59.7% +/- 5.7%), extreme humidity (60.3% +/- 3.9%) or in room conditions (63.6% +/- 3.2%) (p < 0.001). DC of an RBC measured by micro-Raman spectroscopy may be affected by differences in sample preparation and storing conditions, making it difficult to extrapolate data from in vitro studies into clinically relevant information.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...