Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Quality of ECG monitoring with a miniature ECG recorder
Andreas Janata1, Miguel E Lemmert, James K Russell
1Department of Emergency Medicine, Medical University of Vienna, Austria. andreas.janata@meduniwien.ac.at
Background:
Long-term monitoring of patients at risk of arrhythmias would benefit from a miniaturized device. This study evaluated the quality of electrocardiogram (ECG) signals recorded by a miniaturized ECG recorder.
Methods:
ECG data were concurrently recorded with an investigational device (Philips Medical Systems, Seattle, WA, USA) and a Holter recorder from patients with cardiac-related symptoms at the emergency department of a tertiary care university hospital. The device was attached in one of four locations (L1: below left clavicle, L2: midsternal, L3: below left breast, L4: left anterior axillary line in 5th intercostal space). Selected ECG strips were analyzed for atrial activity, QRS width, and basic rhythm by two physicians. Patients were divided into groups based on their number of strips (A 2-5, B 6-9, C 10-21) for descriptive presentation of the data. For statistical analyses, nonlinear mixed-effects models were used.
Results:
In 90 patients, 574 pairs of strips were analyzed. In L1 (n = 37), agreement between the device and the Holter recorder on presence of P wave was 58-80% in groups A-C and in L2 (n = 28):94-98%, L3 (n = 12):30-72%, and L4 (n = 13):0-70%; on PR interval in L1:58-80%, L2:94-98%, L3:30-62%, and L4:0-70%; on rhythm in L1:56-79%, L2:94-98%, L3:30-62%, and L4:0-70%; on QRS width in L1:86-100%, L2:88-98%, L3:100%, and L4:96-100%. The agreement of L2 in the parameters P wave, PR interval, and rhythm diagnosis was better than in the other locations (P < 0.01).
Conclusions:
A miniature ECG monitor provided accurate assessment of atrial beats and rhythm diagnosis at a midsternal location and of QRS width at all locations.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Holter Monitor: 24-Hour Monitoring
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...