Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Years of Life Lost of Patients With Early Adenocarcinoma of the Esophagogastric Junction Compared to Esophageal or Gastric Adenocarcinoma. A Registry-Based Study.

Cancer medicine·2026
Same author

Resistance Training Reshapes the Gut Microbiome in a Longitudinal 8-Week Intervention in Sedentary Adults.

Sports medicine - open·2026
Same author

A Novel Technology for Needle-Free Injections of Liquids, Particles and Viable Cells into the Submucosa of the Urethra by a Pressure-Controlled Waterjet Technology.

Biomedicines·2025
Same author

Correction: Curriculum for safe and effective use of artificial intelligence in endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement.

Endoscopy·2025
Same author

Curriculum for safe and effective use of artificial intelligence in endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement.

Endoscopy·2025
Same author

Non-invasive physical plasma activates stimulator of interferon genes pathway in triple negative breast cancer and is associated with increased host immune response.

Frontiers in immunology·2025
Same journal

Adverse events associated with endoscopic retrograde cholangiopancreatography (ERCP) and ERCP-related procedures.

Gastrointestinal endoscopy·2026
Same journal

Quality measures in the design, conduct, and reporting of endoscopic research.

Gastrointestinal endoscopy·2026
Same journal

Location of GI lesions with bleeding potential in patients with iron deficiency anemia: a multicenter prospective study.

Gastrointestinal endoscopy·2026
Same journal

TEMPORARY REMOVAL: Sustainability indicators for gastrointestinal endoscopy: a framework proposed by the Canadian Association of Gastroenterology and the American Society for Gastrointestinal Endoscopy.

Gastrointestinal endoscopy·2026
Same journal

Clinical Outcomes of Primary versus Conversion Endoscopic Ultrasound-Guided Gallbladder Drainage after Percutaneous Drainage: A Multicenter Study.

Gastrointestinal endoscopy·2026
Same journal

Remimazolam versus Midazolam for Moderate Sedation in Gastrointestinal Endoscopy: A Systematic Review and Meta-analysis of Randomized Controlled Trials.

Gastrointestinal endoscopy·2026
See all related articles

Related Experiment Video

Updated: Jul 4, 2026

Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo
06:23

Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo

Published on: August 4, 2018

Colon explosion during argon plasma coagulation

Hendrik Manner1, Nicola Plum, Oliver Pech

  • 1Department of Internal Medicine II, HSK Wiesbaden, Wiesbaden, Germany.

Gastrointestinal Endoscopy
|June 3, 2008
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Basic Research in Plasma Medicine - A Throughput Approach from Liquids to Cells
07:37

Basic Research in Plasma Medicine - A Throughput Approach from Liquids to Cells

Published on: November 17, 2017

Treating Surfaces with a Cold Atmospheric Pressure Plasma using the COST-Jet
06:36

Treating Surfaces with a Cold Atmospheric Pressure Plasma using the COST-Jet

Published on: November 2, 2020

Related Experiment Videos

Last Updated: Jul 4, 2026

Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo
06:23

Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo

Published on: August 4, 2018

Basic Research in Plasma Medicine - A Throughput Approach from Liquids to Cells
07:37

Basic Research in Plasma Medicine - A Throughput Approach from Liquids to Cells

Published on: November 17, 2017

Treating Surfaces with a Cold Atmospheric Pressure Plasma using the COST-Jet
06:36

Treating Surfaces with a Cold Atmospheric Pressure Plasma using the COST-Jet

Published on: November 2, 2020