Four-year water degradation of a total-etch and two self-etching adhesives bonded to dentin
Ali I Abdalla1, Albert J Feilzer
1Department of Restorative Dentistry, Faculty of Dentistry, University of Tanta, Tanta, Egypt. ali_abdalla79@yahoo.com
Objectives:
To evaluate effect of direct and indirect water storage on the microtensile dentin bond strength of one total-etch and two self-etching adhesives.
Methods:
The adhesive materials were: one total-etch adhesive; 'Admira Bond' and two self-etch adhesives; 'Clearfil SE Bond' and 'Hybrid Bond'. Freshly extracted human third molar teeth were used. In each tooth, a Class I cavity (4mmx4mm) was prepared in the occlusal surface with the pulpal floor extending approximately 1mm into dentin. The teeth were divided into three groups (n=18). Each group was restored with the resin composite 'Clearfil APX' using one of the tested adhesives. For each experimental group 3 test procedures (n=6) were carried out: Procedure A: the teeth were stored in water for 24h (control), then sectioned longitudinally, buccolingually and mesiodistally to get rectangular slabs of 1.0-1.2mm thickness on which a microtensile test was carried out. Procedure B: the teeth were also sectioned; however, the slabs were stored in water at 37 degrees C for 4 years before microtensile testing (direct water storage). Procedure C: the teeth were kept in water at 37 degrees C 4 years before sectioning and microtensile testing (Indirect water storage). During microtensile testing the slabs were placed in a universal testing machine and load was applied at cross-head speed of 0.5mm/min.
Results:
For the 24h control, there was no significant difference in bond strength between the three tested adhesives. After 4 years of indirect water storage, the bond strength decreased but the reduction was not significantly different from those of 24h. After 4 years of direct water storage, the bond strengths of all tested adhesives were significantly reduced compared to their 24h results.
Conclusion:
All the tested adhesives showed no reduction in bond strength after indirect water exposure for 4 years. After 4-year direct water exposure, the bond produced by all tested adhesives was unable to resist deterioration.
Related Concept Videos
Waterproofing and Anti-Bacterial Admixtures in Concrete
Waterproofing admixtures render concrete hydrophobic,...
Testing Water Quality
Effect of Sea Water on Concrete
Concrete in areas between tide marks, which undergo...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...