Related Experiment Video
Updated: Jul 4, 2026

Microfluidic Approach to Resolve Simultaneous and Sequential Cytokine Secretion of Individual Polyfunctional Cells
Published on: March 8, 2024
Multiplexed cytokine detection of interstitial fluid collected from polymeric hollow tube implants--a feasibility
Xiangdan Wang1, Michelle R Lennartz, Daniel J Loegering
1Department of Chemistry and Chemical Biology, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, 110 Eighth Street, Troy, NY 12180-3590, USA.
Abstract:
Cytokines are important cellular signaling proteins involved in inflammation, wound healing and are thought to direct the foreign body response to implanted materials. In this work, polyurethane tubes (25 mm length, 1.02 mm i.d., and 1.65 mm o.d.) were implanted into subcutaneous tissue of male Sprague-Dawley rats. The tubes served as the biomaterial and a means to collect the interstitial fluid that would be exchanged within the tube lumen and the surrounding tissue. After 3 and 7 days, the tubes were explanted and cytokines in the fluid were quantified with a multiplexed cytokine immunoassay. Six cytokines, interleukin-1beta (IL-1beta), IL-4, IL-6, IL-10, macrophage chemoattractant protein-1 (MCP-1), and tumor necrosis factor-alpha (TNF-alpha), were simultaneously quantified. All cytokine concentrations with the exception of IL-4 and TNF-alpha ranged between low pg/mL to mid ng/mL levels. Neither TNF-alpha nor IL-4 was detected from any sample. These results illustrate the potential of using the tube materials combined with bead-based immunoassays as a direct method for in vivo collection of multiple cytokines in low microliter sample volumes for fixed day biomaterial implant studies.