Related Experiment Video
Updated: Jul 4, 2026

Nine-Grid Area Division Method: A New Ideal Bone Puncture Region for Percutaneous Vertebroplasty in Lumbar Spine
Published on: August 9, 2024
Modified vertebroplasty using a curved probe: technique and preliminary results
1Department of Neurosurgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea. neuriac@skku.edu
Objective:
One of the main limitations of vertebroplasty is the excessive pressure required for injection of sufficient cement into a vertebral body. Kyphoplasty can be used to reduce injection pressure by making a void with a balloon tamp. The author presents a technique of making small voids to reduce cement delivery pressure during vertebroplasty that involves a simple modification of the conventional technique.
Methods:
The author performed this modified vertebroplasty in 48 patients with an acute vertebral compression fracture. Small voids and micro-connections with the fracture gaps in the vertebral body were created using a curved probe placed into the vertebral body through a working cannula. Visual analogue scale (VAS) scores were measured preoperatively and at 1 week and 3 months postoperatively. Forty patients with osteoporotic VCFs were followed for a mean period of 6months.
Results:
All 48 patients showed a significant reduction in visual analogue pain scores at 1 week and 3 months postoperatively versus preoperative levels (p<0.001, respectively). No device-related complications or major cement leakages that caused postoperative neurological deficits or pulmonary complications were noted.
Conclusion:
The described modification of vertebroplasty involving the creation of small cavities using a curved probe appears to control cement injection easily during the procedures and minimize cement leakage-related complications.