Related Experiment Videos
[Occlusal adjustment and crown finishing in gold-ceramics]
E Romeo1, L Bardelli, A Marchesi
1Università degli Studi di Milano.
Prevenzione & Assistenza Dentale
|January 1, 1991
Abstract:
In the present study the Authors, using the Scanning Electron Microscope (magnification max. = 1.500 X), compare the finishing of gold-porcelain crown's surfaces clinically obtainable, after finishing by diamond points, with the polishing realized by means of glazing laboratory procedures. The survey demonstrates a great difference between the two techniques, showing large furrows on the surfaces when polished using silicon rubber points while they were perfectly smooth when glazed in laboratory.