Standardized uptake value-based evaluations of solitary pulmonary nodules using F-18 fluorodeoxyglucose-PET/computed
Berna Degirmenci1, David Wilson, Charles M Laymon
1Department of Radiology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.
Objective:
Combined positron emission tomography and computed tomography (PET/CT) might improve the accuracy of PET tracer quantification by providing the exact tumour contour from coregistered CT images. We compared various semiquantitative approaches for the characterization of solitary pulmonary nodules (SPNs) using F-18 fluorodeoxyglucose PET/CT.
Methods:
The final diagnosis of 49 SPNs (46 patients) was based on histopathology (n=33) or patient follow-up (n=16). The regions of interest (ROIs) were drawn around lesions based on the CT tumour contour and mirrored to the coregistered PET images. Quantification of F-18 fluorodeoxyglucose uptake was accomplished by calculating the standardized uptake value (SUV) using three different methods based on: activity from the maximum-valued pixel within the tumour (SUV-max); the mean ROI activity within the transaxial slice containing the maximum-valued pixel (SUV-mean); and the mean activity over the full tumour volume (SUV-vol). SUVs were corrected for partial volume effects and normalized by body surface area, lean body weight, and blood glucose. Recovery coefficients for partial-volume correction were derived from phantom studies. The ability of various SUVs to differentiate between benign and malignant SPNs was determined by calculating the area under the receiver operating characteristic (ROC) curves.
Results:
Twenty-six SPNs were malignant and 23 were benign. The area under the ROC curve was 0.78 for SUV-mean, 0.83 for SUV-max, and 0.78 for SUV-vol. SUV-max and its normalizations yielded the highest area under the ROC curve (0.83-0.85); SUV-mean-partial volume corrected-lean body weight resulted in the lowest area under the ROC curve (0.76). At a specificity of 80%, SUV-max-body surface area provided the highest sensitivity (81%) and accuracy (80%) to detect malignant SPN. Using SUV-max with a cutoff of 2.4 at a specificity of 80% resulted in a sensitivity of 62% (accuracy 71%).
Conclusion:
Various normalizations applied to SUV-max provided the highest diagnostic accuracy for characterization of SPNs. Quantification methods using the exact tumour contour derived from CT in combined PET/CT imaging (ROI mean activity within a single transaxial slice and mean tumour volume activity) did not result in improved differentiation between benign and malignant SPN. Obtaining SUV-max might be sufficient in the clinical setting.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET