Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Comparability and reproducibility of the carotid-femoral pulse wave velocity measurements using a multi-element
1Department of Clinical Pharmacology and Therapeutics, Graduate School of Medicine, University of the Ryukyus, Okinawa, Japan.
Abstract:
To evaluate the comparability and reproducibility of the carotid-femoral pulse wave velocity (PWV) measured by the newly developed device compared to that measured by the standard device and the validity of brachial-ankle PWV as a substitute of carotid-femoral PWV. We measured aortic PWV twice in 21 normotensive males by using the standard devices and the newly developed device. We also measured brachial-ankle PWV in the same subjects. There was a strong, significant correlation between aortic (carotid-femoral) PWV measured by using two different devices (r = 0.741, P = 0.00012). Interquartile range of the differences of carotid-femoral PWV measured by Form (0.75 m/s (-0.36, 0.39)) was smaller than that by Complior (1.67 m/s (-1.03, 0.63)). There was no correlation between carotid-femoral PWV, measured by either device, and brachial ankle PWV. Our present results suggest that carotid-femoral PWV measured by using Form was comparable to, and may be more reproducible than, that measured by Complior that has been widely used as a predictable marker for cardiovascular events. Our results also suggest brachial-ankle PWV may not be a substitute for carotid-femoral PWV.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...