Related Experiment Video
Updated: Jul 4, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and
Peter F Choong1, Michelle M Dowsey, James D Stoney
1Department of Orthopaedics, St Vincent's Hospital, University of Melbourne, Melbourne, Victoria, Australia.
Abstract:
This is a randomized prospective controlled trial comparing the alignment, function, and patient quality-of-life outcomes between patients undergoing conventional (CONV) and computer-assisted (CAS) knee arthroplasty. One hundred and fifteen patients (60 CAS, 55 CONV) underwent cemented total knee arthroplasty. Three patients were lost to follow-up. Eighty-eight percent (CAS) vs 61% (CONV) of knees achieved a mechanical axis within 3 degrees of neutral (P = .003). Aligning femoral rotation with the epicondylar axis was accurately achieved in CAS and CONV with no significant difference. Patients with coronal alignment within 3 degrees of neutral had superior International Knee Society and Short-Form 12 physical scores at 6 weeks, 3 months, 6 months, and 12 months after surgery. Computer-assisted total knee arthroplasty achieves greater accuracy in implant alignment and this correlates with better knee function and improved quality of life.