Related Experiment Video
Updated: Jul 4, 2026

A Computational Modeling Approach to Investigate the Influence of Hyperthermia on the Tumor Microenvironment
Published on: December 1, 2023
Preanalytical, analytical, and computational factors affect homeostasis model assessment estimates
Susan E Manley1, Stephen D Luzio, Irene M Stratton
1Clinical Biochemistry, University Hospital Birmingham NHS Foundation Trust, University of Birmingham, Birmingham, UK. susan.manley@uhb.nhs.uk
Objective:
We investigated how beta-cell function and insulin sensitivity or resistance are affected by the type of blood sample collected or choice of insulin assay and homeostatis model assessment (HOMA) calculator (http://www.dtu.ox.ac.uk).
Research Design And Methods:
Insulin was measured using 11 different assays in serum and 1 assay in heparinized plasma. Fasting subjects with normoglycemia (n = 12), pre-diabetes, i.e., impaired fasting glucose or impaired glucose tolerance (n = 18), or type 2 diabetes (n = 67) were recruited. Patients treated with insulin or those who were insulin antibody-positive were excluded. HOMA estimates were calculated using specific insulin (SI) or radioimmunoassay (RIA) calculators (version 2.2).
Results:
All glucose values were within model (HOMA) limits but not all insulin results, as 4.3% were <20 pmol/l and 1% were >300 pmol/l. beta-Cell function derived from different insulin assays ranged from 67 to 122% (median) for those with normoglycemia (P = 0.026), from 89 to 138% for those with pre-diabetes (P = 0.990), and from 50 to 81% for those with type 2 diabetes (P < 0.0001). Furthermore, insulin resistance ranged from 0.8 to 2.0 (P = 0.0007), from 1.9 to 3.2 (P = 0.842), and from 1.5 to 2.9 (P < 0.0001), respectively. This twofold variation in HOMA estimates from the various insulin assays studied in serum may be significant metabolically. Insulin was 15% lower in heparinized plasma (used in the original HOMA study) compared with serum, which is now more commonly used. beta-Cell function differed by 11% and insulin resistance by 15% when estimates derived from specific insulin were calculated using the RIA rather than the SI calculator.
Conclusions:
To enable comparison of HOMA estimates among individuals and different research studies, preanalytical factors and calculator selection should be standardized with insulin assays traceable to an insulin reference method procedure.
More Related Videos
08:01A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli
Published on: August 12, 2016
08:33A Cross-Disciplinary and Multi-Modal Experimental Design for Studying Near-Real-Time Authentic Examination Experiences
Published on: September 4, 2019
Related Concept Videos
Homeostatic Imbalance
However, sometimes these feedback loops fail,...
What is Homeostasis?
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Mechanistic Models: Compartment Models in Individual and Population Analysis
Positive and Negative Feedback Loops
Pharmacokinetic Models: Overview
There are three primary types of models: empirical, compartment, and physiological. Empirical models, with minimal assumptions,...