Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
Color Doppler sonography in the evaluation of erectile dysfunction: patterns of temporal response to papaverine
S W Fitzgerald1, S J Erickson, W D Foley
1Department of Radiology, Northwestern Memorial Hospital, Chicago, IL 60611.
Abstract:
Most studies of duplex Doppler sonography for the assessment of erectile dysfunction involve determination of peak systolic velocities 5 min after intracavernosal injection of papaverine. The purpose of this study was to determine the effect of the timing of Doppler measurements of flow after papaverine injection for establishing the presence of arterial and venous abnormalities. Color Doppler sonography was performed in 75 patients for evaluation of vasculogenic impotence. After intracavernosal injection of 60 mg of papaverine, measurements of peak systolic and end-diastolic velocities were obtained in each cavernosal artery at 5-min intervals for a total of 30 min. A peak systolic velocity of less than 25 cm/sec was used as the threshold for arterial insufficiency. An end-diastolic velocity of greater than 5 cm/sec was used to predict venous incompetence. Scanning was performed for direct assessment of dorsal venous flow. Thirty patients were subsequently evaluated by cavernosometry and cavernosography. In most patients (76%), maximum response to papaverine was achieved within the first 5 min. In eight patients, significant increases in systolic velocity were seen only after 5 min. In 10 patients, significant changes in end-diastolic velocity between 5 and 30 min resulted in diagnostic reclassification. Data acquisition for 30 min significantly improved the sensitivity (95%) and specificity (83%) for the prediction of venous incompetence in patients with correlative cavernosography. Transient, early dorsal vein flow was noted in normal subjects. Persistent dorsal vein flow had an 80% sensitivity and 100% specificity for venous incompetence. Our results suggest that, when using color Doppler sonography, gathering data for 30 min may improve the prediction of vasculogenic impotence.
Related Concept Videos
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation