Related Experiment Video
Updated: Jul 4, 2026

A Lipid Extraction and Analysis Method for Characterizing Soil Microbes in Experiments with Many Samples
Published on: July 16, 2017
Metrological effectiveness of an analytical method for volatile organic compounds standard materials using
Takuro Watanabe1, Kenji Kato, Kin-ichi Tsunoda
1Organic Standards Section 1, Organic Analytical Chemistry Division, National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan. watanabe-takuro@aist.go.jp
Abstract:
The metrological effectiveness of an analytical method using the post-column reaction GC/FID system was evaluated. The SI-traceable certified reference material (CRM), the eight ester phthalates mixture standard solution, was used as a sample. We assigned specific value to n-eicosane and it was used as an internal standard. A known quantity of n-eicosane was added to the CRM, and the mixture was measured with the post-column reaction GC/FID system. Six phthalate esters were chromatographically separated and determined. The assigned values by our system are in good agreement with the certified values of the CRM, and the combined uncertainties of the measurements by the present system were better than those of the CRM. Our method is classified as a primary ratio method and the specific values of many organic compounds can be assigned very precisely by using a small number of reference materials. Also, the method can make it possible to avoid the purity determination of raw materials and directly to assign their specific values after the preparation of the standard mixture. Conclusively, this post-column reaction GC/FID system is very effective for the chemical metrology.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...