Performance of oxygen delivery devices when the breathing pattern of respiratory failure is simulated
M A B Sim1, P Dean, J Kinsella
1University Department of Anaesthesia, Glasgow Royal Infirmary, Glasgow, UK. Malcolm.Sim@ggc.scot.nhs.uk
Abstract:
Oxygen is the commonest drug prescribed in hospitals. The inhaled concentration is altered by the administered oxygen flow rate, the characteristics of the delivery device and the patient's respiratory pattern. Using healthy volunteers we measured the inspired oxygen concentration achieved with different devices both at rest and when the breathing pattern of respiratory failure was simulated by binding the subjects' chests until the forced expiratory volume in 1 s was reduced by > 50% and the respiratory rate was > 25 breaths.min(-1). With this respiratory pattern, there was a statistically significant fall in F(I)o(2) while administering oxygen via a Hudson mask at 4 l.min(-1) (23.8% (95% CI 17.4-30.3%) reduction), 12 l.min(-1), humidified (17.8% (95% CI 8.8-26.7%) reduction) and 24 l.min(-1), humidified (12.2% (95% CI 5.0-19.3%) reduction). There was no statistically significant change with a nonrebreathing (reservoir) mask at 15 and 110 l.min(-1) or with a Vapotherm 2000i at 40 l.min(-1), humidified, via nasal prongs. We conclude that the F(I)o(2) delivered by high flow devices is unaffected when the breathing pattern of respiratory failure is simulated. The F(I)o(2) achieved at rest by a nonrebreathing mask (0.68) is less than that often quoted in the literature.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Acute Respiratory Failure-IV