Electronic post-compensation of WDM transmission impairments using coherent detection and digital signal processing
Xiaoxu Li1, Xin Chen, Gilad Goldfarb
1CREOL, The College of Optics & Photonics, University of Central Florida, 4000 Central Florida Blvd., Orlando, FL 32816-2700, USA.
Optics Express
|June 11, 2008
Abstract:
A universal post-compensation scheme for fiber impairments in wavelength-division multiplexing (WDM) systems is proposed based on coherent detection and digital signal processing (DSP). Transmission of 10 x 10 Gbit/s binary-phase-shift-keying (BPSK) signals at a channel spacing of 20 GHz over 800 km dispersion shifted fiber (DSF) has been demonstrated numerically.
Related Concept Videos
Reconstruction of Signal using Interpolation
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
Frequency-Domain Interpretation of PD Control
Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the system's...
The proportional control gain, combined with the system's...
Time-Domain Interpretation of PD Control
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
Power Factor Correction
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
Doppler Effect - II
The Doppler effect has several practical, real-world applications. For instance, meteorologists use Doppler radars to interpret weather events based on the Doppler effect. Typically, a transmitter emits radio waves at a specific frequency toward the sky from a weather station. The radio waves bounce off the clouds and precipitation and travel back to the weather station. The radio frequency of the waves reflected back to the station appears to decrease if the clouds or precipitation are moving...
Downstream Processing
Downstream processing begins once fermentation is complete and involves a series of steps to recover and purify products such as acids, vitamins, antibiotics, or proteins.Cell HarvestingFor example, for intracellular protein-based products, the first step is harvesting the cells. This is typically achieved using centrifugation or filtration to separate the cells from the liquid phase.Cell Disruption for Intracellular ProductsIf the target product is intracellular, the harvested cells must be...

