Phase-contrast tomography of single-material objects from few projections
G R Myers1, D M Paganin, T E Gureyev
1School of Physics, Monash University, VIC 3800, Australia. Glenn.Myers@sci.monash.edu.au
Abstract:
A method is presented for quantitative polychromatic cone-beam phase-contrast tomographic imaging of a single-material object from few projections. This algorithm exploits the natural combination of binary tomography with a phase-retrieval method that makes explicit use of the single-material nature of the sample. Such consistent use of a priori knowledge reduces the number of required projections, implying significantly reduced dose and scanning time when compared to existing phase-contrast tomography methods. Reconstructions from simulated data sets are used to investigate the effects of noise and establish a minimum required number of projections. An experimental demonstration is then given, using data from a point-projection X-ray microscope. Here, the complex distribution of refractive index in a sample containing several nylon fibers with diameters between 100 microm and 420 microm is reconstructed at a spatial resolution of approximately 4 microm from 20 polychromatic phase-contrast projection images with a mean photon energy of 8.4 keV.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies III: Computed Tomography