Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jul 4, 2026

A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood
08:17

A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood

Published on: February 8, 2016

Antibody-bound cell microarray for immunophenotyping: surface modification and lymphocyte subpopulations.

Yasuo Fujii1, James M Anderson, Takehisa Matsuda

  • 1Department of Biomedical Engineering, Graduate School of Medicine, Kyushu University, Higashiku, Fukuoka 812-8582, Japan.

Journal of Biomedical Materials Research. Part B, Applied Biomaterials
|June 12, 2008
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The community engagement and empowerment cycle: FAIRagro's framework to foster cultural change towards FAIR RDM practices in agrosystem science and beyond.

Journal of integrative bioinformatics·2026
Same author

Increasing levels of craniocervical junction fusion increase cervical annulus stress and facet joint forces while decreasing cervical motion.

The spine journal : official journal of the North American Spine Society·2026
Same author

Behavior of Locked Intramedullary Implants Spanning the Distal Femoral Growth Plate: Results From an Ovine Model.

Journal of pediatric orthopedics·2025
Same author

A reflection on Arnold Caplan, the father of MSC.

Best practice & research. Clinical haematology·2025
Same author

Allan Hoffman - My friend.

Journal of controlled release : official journal of the Controlled Release Society·2024
Same author

Differential effects of macrophage subtype-specific cytokines on fibroblast proliferation and endothelial cell function in co-culture system.

Journal of biomedical materials research. Part A·2024

Antibody microarrays precisely quantify blood cell types for medical diagnosis. This high-throughput method offers reliable immunophenotyping using specific antibodies to cluster of differentiation (CD) antigens.

Area of Science:

  • Biomedical Engineering
  • Immunology
  • Materials Science

Background:

  • Antibody-based cell microarrays are crucial for high-throughput diagnostics.
  • Precise surface design is essential for biological specificity, reliability, and validity.
  • Quantitative immunophenotyping requires robust cell microarray platforms.

Purpose of the Study:

  • To quantitatively evaluate immunophenotyping using a cell microarray.
  • To assess the specificity and reliability of antibody fixation on microarrays.
  • To validate the accuracy of CD4/CD8 subset ratio determination.

Main Methods:

  • Fabrication of microarrays using photopatterned self-assembled monolayers of alkanethiols.
  • Covalent fixation of anti-CD4 and anti-CD8 antibodies onto carboxylated domains.

More Related Videos

Colorectal Cancer Cell Surface Protein Profiling Using an Antibody Microarray and Fluorescence Multiplexing
15:17

Colorectal Cancer Cell Surface Protein Profiling Using an Antibody Microarray and Fluorescence Multiplexing

Published on: September 25, 2011

Related Experiment Videos

Last Updated: Jul 4, 2026

A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood
08:17

A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood

Published on: February 8, 2016

Colorectal Cancer Cell Surface Protein Profiling Using an Antibody Microarray and Fluorescence Multiplexing
15:17

Colorectal Cancer Cell Surface Protein Profiling Using an Antibody Microarray and Fluorescence Multiplexing

Published on: September 25, 2011

  • Verification of antibody fixation using confocal laser scanning microscopy and dye staining.
  • Validation of cell adhesion specificity using flow cytometry and magnetic bead isolation.
  • Main Results:

    • Microarrays demonstrated precise, high-specificity binding of peripheral blood mononuclear cells expressing CD4 or CD8 antigens.
    • Confocal microscopy confirmed near-complete antibody conversion during fixation.
    • CD4/CD8 subset ratios determined by microarrays closely matched flow cytometry results.
    • The microarray platform exhibited high biological specificity, reliability, and validity.

    Conclusions:

    • Covalently fixed antibodies on microarrays provide a foundation for high-throughput immunophenotyping.
    • This technology supports accurate quantitative evaluation for medical diagnosis.
    • The developed microarray technique offers a reliable tool for analyzing blood cell populations.