Related Experiment Video
Updated: Jul 4, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Intraoral open reduction and internal fixation of displaced mandibular angle fractures using a specific ad hoc
Paolo Scolozzi1, Bertrand Jaques
1Division of Oral and Maxillofacial Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland.
Objectives:
To preliminarily evaluate prospectively the accuracy and reliability of a specific ad hoc reduction-compression forceps in intraoral open reduction of transverse and displaced mandibular angle fractures.
Study Design:
We analyzed the clinical and radiologic data of 7 patients with 7 single transverse and displaced angle fractures. An intraoral approach was performed in all of the patients without using perioperative intermaxillary fixation. A single Arbeitsgemeinschaft Osteosynthese (AO) unilock reconstruction plate was fixed to each stable fragment with 3 locking screws (2.0 mm in 5 patients and 2.4 mm in 2 patients) at the basilar border of the mandible, according to AO/American Society of Internal Fixation (ASIF) principles. Follow-up was at 1, 3, 6, and 12 months, and we noted the status of healing and complications, if any.
Results:
All of the patients had satisfactory fracture reduction as well as a successful treatment outcome without complications.
Conclusion:
This preliminary study demonstrated that the intraoral reduction of transverse and displaced angle fractures using a specific ad hoc reduction-forceps results in a high rate of success.