Related Experiment Video
Updated: Jul 4, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Built-in defect of a biological pericardial aortic prosthesis?
Dimitrios Buklas1, Massimo Massetti, Eugenio Neri
1Department of Thoracic and Cardiovascular Surgery, Jean-Minjoz Hospital, Besançon, France. buklas@free.fr
Abstract:
We report a case on an early complication of a biological pericardial tissue valve in the aortic position that required emergency replacement. One of the three leaflets of the valve was stuck open in a fixed-open position and would not unfold in diastole. This resulted in severe aortic insufficiency, diagnosed by standard postoperatory echocardiography and confirmed in the operating room.
Related Concept Videos
Aortic Regurgitation I: Introduction
Aneurysm III: Interprofessional Care
Aneurysm I: Introduction
Mitral Valve Prolapse I: Introduction
Pericarditis I: Introduction
Rheumatic Heart Disease I: Introduction