Direct imaging of radionuclide-produced electrons and positrons with an ultrathin phosphor
Liying Chen1, Lisa S Gobar, Negar G Knowles
1Department of Radiology, University of Arizona, Tucson, Arizona 85724, USA.
Unlabelled:
Current electron detectors are either unable to image in vivo or lack sufficient spatial resolution because of electron scattering in thick detector materials. This study was aimed at developing a sensitive high-resolution system capable of detecting electron-emitting isotopes in vivo.
Methods:
The system uses a lens-coupled charge-coupled-device camera to capture the scintillation light excited by an electron-emitting object near an ultrathin phosphor. The spatial resolution and sensitivity of the system were measured with a 3.7-kBq (90)Y/(90)Sr beta-source and a 70-microm resin bead labeled with (99m)Tc. Finally, we imaged the (99m)Tc-pertechnetate concentration in the mandibular gland of a mouse in vivo.
Results:
Useful images were obtained with only a few hundred emitted beta particles from the (90)Y/(90)Sr source or conversion electrons from the (99m)Tc bead source. The in vivo image showed a clear profile of the mandibular gland and many fine details with exposures of as low as 30 s. All measurements were consistent with a spatial resolution of about 50 microm, corresponding to 2.5 detector pixels with the current camera.
Conclusion:
Our new electron-imaging system can image electron-emitting isotope distributions at high resolution and sensitivity. The system is useful for in vivo imaging of small animals and small, exposed regions on humans. The ability to image beta particles, positrons, and conversion electrons makes the system applicable to most isotopes.
More Related Videos
10:16Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Photoluminescence: Applications
Determination of Crystal Structures
Transmission Electron Microscopy
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...