Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Determination of Crystal Structures01:29

Determination of Crystal Structures

In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...
X-ray Diffraction of Biological Samples01:10

X-ray Diffraction of Biological Samples

X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are  scattered by the electron clouds around the sample atoms. The  X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Single exposure X-ray nano-tomography in the near-field Fresnel regime with multilayer Laue lenses.

Optics express·2025
Same author

Corrigendum: Dark-field X-ray microscopy for multiscale structural characterization.

Nature communications·2015
Same author

Dark-field X-ray microscopy for multiscale structural characterization.

Nature communications·2015
Same author

Three-dimensional orientation mapping in the transmission electron microscope.

Science (New York, N.Y.)·2011
Same author

A triple-crystal diffractometer for high-energy synchrotron radiation at the HASYLAB high-field wiggler beamline BW5.

Journal of synchrotron radiation·2006
Same author

A conical slit for three-dimensional XRD mapping.

Journal of synchrotron radiation·2006
Same journal

Launching a new era for Short Communications in Journal of Synchrotron Radiation.

Journal of synchrotron radiation·2026
Same journal

Sagittal collimating diaboloid: a new grazing-incidence mirror surface for higher-throughput resonant inelastic X-ray scattering spectrometers.

Journal of synchrotron radiation·2026
Same journal

Synchrotron X-ray tomography and spectroscopy in numismatics: disclosing counterfeit practices in medieval silver coins.

Journal of synchrotron radiation·2026
Same journal

The Big Data Science Center at the Shanghai Synchrotron Radiation Facility: the architecture of the superfacility.

Journal of synchrotron radiation·2026
Same journal

A robotic and high-throughput X-ray micro-computed tomography workflow.

Journal of synchrotron radiation·2026
Same journal

Evolution of hierarchical phase-contrast tomography on the European Synchrotron beamlines BM05 and BM18: a whole adult human brain imaging case study.

Journal of synchrotron radiation·2026
See all related articles

Related Experiment Video

Updated: Jul 4, 2026

Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
11:27

Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2

Published on: December 8, 2016

A high-spatial-resolution three-dimensional detector array for 30-200 keV X-rays based on structured scintillators.

U L Olsen1, S Schmidt, H F Poulsen

  • 1Center for Fundamental Research: Metal Structures in Four Dimensions, Risø National Laboratory, DK-4000 Roskilde, Denmark. ulrik.lund.olsen@risoe.dk

Journal of Synchrotron Radiation
|June 17, 2008
PubMed
Summary
This summary is machine-generated.

This study introduces a novel 3D X-ray detector using structured scintillators for improved imaging. Simulations show high spatial resolution and efficiency, enabling advanced imaging algorithms.

More Related Videos

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
07:48

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue

Published on: September 30, 2022

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

Related Experiment Videos

Last Updated: Jul 4, 2026

Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
11:27

Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2

Published on: December 8, 2016

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
07:48

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue

Published on: September 30, 2022

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

Area of Science:

  • Medical Imaging
  • Photon Detection
  • Materials Science

Background:

  • Conventional X-ray detectors face limitations in spatial resolution and efficiency.
  • Developing advanced detectors is crucial for enhanced medical imaging and scientific research.
  • Structured scintillators offer potential for improved X-ray detection performance.

Purpose of the Study:

  • To describe a novel three-dimensional (3D) X-ray detector for imaging photons in the 30-200 keV range.
  • To theoretically analyze and simulate the performance of this new detector design.
  • To evaluate its potential for improved spatial resolution, efficiency, and advanced imaging applications.

Main Methods:

  • The detector utilizes semi-transparent structured scintillators composed of silicon waveguides filled with Cesium Iodide (CsI).
  • Theoretical analysis and detailed simulations were performed to assess detector performance.
  • Investigated parameters include spatial resolution, efficiency, and cross-talk between detector layers.

Main Results:

  • A spatial resolution of 1 micrometer is achievable with current hardware.
  • Detector screen resolution is primarily determined by pitch up to 100 keV.
  • Efficiency improvements of 5-15 times compared to homogeneous screens were demonstrated.
  • Cross-talk between detector screens was found to be negligible.

Conclusions:

  • The 3D X-ray detector design offers significant improvements in spatial resolution and efficiency.
  • The negligible cross-talk and high performance enable advanced imaging techniques like ray-tracing and super-resolution.
  • This technology holds promise for next-generation X-ray imaging systems.