Polychlorinated biphenyls in contaminated soil samples evaluated by GC-ECD with dual-column and GC-HRMS
Giuliana Bianco1, Giuseppe Novario, Dominga Bochicchio
1Dipartimento di Chimica, Università degli Studi della Basilicata, Via N. Sauro, 85-85100 Potenza, Italy.
Abstract:
We present and compare results obtained from the analysis of polychlorinated biphenyls (PCBs) of a limited number of contaminated soil samples collected in three areas of Basilicata region (south of Italy). The levels of PCBs were evaluated by using two analytical methods: (i) parallel dual-column gas-chromatography with dual electron capture detectors (GC-ECD) and (ii) gas-chromatography coupled to high-resolution mass spectrometry (GC-HRMS) via electron impact ionization (EI) in the multiple ion monitoring mode (MIM, two ions per compound). Two extraction methods prior to sample cleanup were also examined: microwave-assisted extraction (MAE) and ultrasonic-assisted extraction (UAE). The MAE was the extraction procedure adopted using acetone/n-hexane (1:1, v/v) as it is mainly characterized by higher sample throughput and allowed reduced consumption of organic solvents. While extraction and analysis of spiked soil samples showed the applicability of both methods, systematic differences between the results were obtained for the sum of PCBs as a result of some non-detected congeners by GC-ECD compared with GC-HRMS. Indeed, high resolution MS using EI mode (electron energy 40eV) with a resolving power of 10,000 provides additional information about the contamination pattern. The GC-ECD screening of 11 soil samples led to just one sample non-compliant to as it was close to the guide value for soils fixed by the Italian legislation (i.e., 60ppb for private or urban soil). Using GC-HRMS, the amount of all PCBs found ranged from 5.4 to 127ppb with five soil samples non-compliant to the guide value. The number of identified congeners ranged from 1 to 9 and 9 to 18 using dual-column GC-ECD and GC-HRMS, respectively.
More Related Videos
09:39Physical, Chemical and Biological Characterization of Six Biochars Produced for the Remediation of Contaminated Sites
Published on: November 28, 2014
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II