Predictive accuracy of electrophysiologic localization of accessory pathways
W S Teo1, G J Klein, G M Guiraudon
1Department of Medicine, University Hospital, London, Ontario, Canada.
Abstract:
Operative ablation of accessory pathways depends critically on preoperative localization when technical limitations preclude complete intraoperative mapping. To assess the accuracy of localization, 345 patients undergoing operative ablation were studied; 316 (91.6%) had a single accessory pathway and 29 (8.4%) had multiple accessory pathways. The electrophysiologic study was diagnostically complete and accurate in 294 patients (93%) with a single accessory pathway and 19 (61%) with multiple accessory pathways. A left lateral accessory pathway was most accurately localized with excellent sensitivity (99%) and positive predictive value (98.5%). Diagnostic errors occurred in 33 patients because of 1) incorrect localization (n = 16), 2) failure to detect a second pathway (n = 9), and 3) diagnosis of a second pathway not verified intraoperatively (n = 8). Multiple pathways were more prevalent in the group with errors (33.3% vs. 5.8%, p = 0.0001), as were unidirectional pathways (48.5% vs. 24.3%, p = 0.003). It is concluded that preoperative localization of accessory pathways is sufficiently accurate to allow intraoperative mapping to be brief and focused.