Combining chip-ESI with APLI (cESILI) as a multimode source for analysis of complex mixtures with
Philippe Schmitt-Kopplin1, Matthias Englmann, Ramon Rossello-Mora
1German Research Center for Environmental Health, Institute for Ecological Chemistry, Helmholtz Zentrum München, Ingoldstaedter Landstrasse 1, 85764, Neuherberg, Germany.
Abstract:
Recently we have established atmospheric-pressure laser ionisation (APLI) as a method for coupling time-of-flight mass spectrometric detectors (TOF MS) with chromatographic systems (HPLC and GC) to allow two-photon ionisation of non-polar aromatic compounds. Here we demonstrate that APLI can be combined with chip-electrospray ionisation (cESI) coupled to Fourier-transform-ion cyclotron resonance mass spectrometry (FT-ICR MS) for ultrahigh-resolution analysis of complex samples. With the laser turned off, the analytes are ionised only by ESI, whereas when the laser is switched on non-polar aromatic substances also are ionised. In combination with the extremely high mass resolution of an FT-ICR MS, simultaneous qualitative analysis of polar and non-polar analytes is possible in both positive and negative modes, as is exemplified with a crude oil sample. Nevertheless, ion suppression was observed (up to ca. 70% for D(10)-pyrene) and thus sample preparation with chromatographic or electrophoretic pre-separation is necessary for quantitative analysis of targets. In addition, for the first time, the dopant-assisted APLI method in combination with cESI (DA-cESILI) was used for determination of 1-nitrocoronene.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Tandem Mass Spectrometry