Related Experiment Video
Updated: Jul 4, 2026

The Diffusion of Passive Tracers in Laminar Shear Flow
Published on: May 1, 2018
Effects of plume spacing and flowrate on destratification efficiency of air diffusers
Kyungtaek Yum1, Sung Hoon Kim, Heekyung Park
1Korea Water Resources Corporation (KWATER), Republic of Korea.
Abstract:
This study adopts techniques of computational fluid dynamics (CFD) to analyze the combined effect of adjacent plumes of an air-diffuser system on its destratification efficiency. Lab experiments were carried out to calibrate and verify the CFD models in thermally stratified freshwater. The CFD simulation and lab experiment results were analyzed to relate destratification efficiency with four non-dimensional variables. The results indicate that destratification number, D(N), has the best relationship that includes air flowrate, stratification frequency, water depth, and bubble slip velocity. Since plume spacing and air flowrate are the major control variables of the system, especially in the field, two charts showing the relationships between destratification efficiency, plume spacing, and destratification number are developed for guiding their control in its design and operation.
Related Concept Videos
Poiseuille's Law and Reynolds Number
Laminar Flow
Pipe Flowrate Measurement
The orifice meter is a simple,...
Laminar Flow: Problem Solving
Design Example: Designing a Residential Plumbing System
Steady, Laminar Flow Between Parallel Plates