Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Photonic Analogy of Continuous Time Crystal Induced by Photorefractive Effect.

Physical review letters·2026
Same author

Feasibility and application of an adsorption model for coal pore structure analysis through N<sub>2</sub> adsorption.

Scientific reports·2026
Same author

A portable and low-cost fluorescence reader for near-patient nucleic acid amplification assays.

Biomedical microdevices·2026
Same author

Stochasticity in cancer immunotherapy stems from rare but functionally critical Spark T cells.

Cell·2026
Same author

3D printed microcyclones for enhanced collection, separation, and recovery of sub-micrometer bioaerosols.

Sensors and actuators. B, Chemical·2026
Same author

Poly(lactic-<i>co</i>-glycolic acid) for reagent storage and controlled release in thermoplastic microfluidics.

Lab on a chip·2026
Same journal

Tunable self-assembling cellular microarray for single-neutrophil vital and suicidal extracellular traps.

Lab on a chip·2026
Same journal

Precise programmable tumor cell subpopulation sorting <i>via</i> an electromagnetic microfluidic platform.

Lab on a chip·2026
Same journal

Bridging dimensions: combining one- and two-photon 3D printing for microfluidic device fabrication.

Lab on a chip·2026
Same journal

Microfluidic rare cell analysis beyond counting: workflow design from enrichment to multi-omics.

Lab on a chip·2026
Same journal

A sperm racetrack to separate sperm by swim speed.

Lab on a chip·2026
Same journal

Controlled encapsulation and droplet size prediction in two-step microfluidic double emulsions.

Lab on a chip·2026
See all related articles

Related Experiment Video

Updated: Jul 4, 2026

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

Optimization of sample transfer in two-dimensional microfluidic separation systems.

Shuang Yang1, Jikun Liu, Don L DeVoe

  • 1Department of Mechanical Engineering, University of Maryland, College Park, MD, USA.

Lab on a Chip
|June 28, 2008
PubMed
Summary
This summary is machine-generated.

This study presents an optimized microfluidic chip design for improved multidimensional separations. The new design ensures uniform sample transfer and minimizes leakage, enhancing overall performance in microfluidic devices.

More Related Videos

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
07:57

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics

Published on: November 10, 2014

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

Related Experiment Videos

Last Updated: Jul 4, 2026

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
07:57

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics

Published on: November 10, 2014

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
08:20

Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets

Published on: February 22, 2016

Area of Science:

  • Microfluidics
  • Analytical Chemistry
  • Separation Science

Background:

  • Multidimensional microfluidic separation systems face challenges like non-uniform sample transfer, leakage, and injection plug tailing.
  • These issues significantly degrade the performance of two-dimensional separation systems.
  • Optimizing chip design is crucial for enhancing the efficiency and reliability of microfluidic separations.

Purpose of the Study:

  • To develop and validate an optimized microfluidic chip design for improved multidimensional separations.
  • To address challenges of non-uniform sample transfer, leakage, and injection plug tailing in microfluidic systems.
  • To enhance the overall performance of two-dimensional microfluidic separation systems.

Main Methods:

  • Utilized numerical and analytical modeling to investigate microfluidic chip performance.
  • Developed an optimized chip design incorporating multidimensional backbiasing and angled channel geometry.
  • Experimentally validated the optimized design using a microfluidic chip with five second-dimension channels.

Main Results:

  • The optimized chip design ensures leakage-free and uniform interdimensional sample transfer.
  • The design effectively minimizes injected sample plug lengths in the second dimension.
  • Experimental validation confirmed the predicted improvements in microfluidic separation performance.

Conclusions:

  • The proposed multidimensional backbiasing and angled channel geometry significantly enhance microfluidic chip design.
  • This optimized design overcomes key limitations in current multidimensional microfluidic separation systems.
  • The findings pave the way for more efficient and reliable microfluidic analytical devices.