Related Experiment Video
Updated: Jul 4, 2026

Source and Route of Pyrrolizidine Alkaloid Contamination in Tea Samples
Published on: September 28, 2022
Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples
1Department of Chemistry, Faculty of Science, Guilan University, P.O. Box 1914, Rasht 0098, Iran. arvand@guilan.ac.ir
Abstract:
A novel ion-selective PVC membrane sensor for Al(III) ions based on 6-(4-nitrophenyl)-2-phenyl-4-(thiophen-2-yl)-3,5-diaza-bicyclo[3.1.0]hex-2-ene (NTDH) as a new ionophore has been prepared and studied. The electrode exhibit a good response for aluminum ion over concentration range of 1.0x10(-6) to 1.0x10(-1) mol L(-1) with a Nernstian slope of 19.6+/-0.4 mV per decade and low detection limit of 6.3x10(-7) mol L(-1). The best performance was obtained with membrane composition 30% poly(vinyl chloride), 62% acetophenone, 5% oleic acid, 3% ionophore and 2 ml tetrahydrofuran. NTDH-based electrode was suitable for aqueous solutions of pH 3. It has relatively fast response time (approximately 10 s) and can be used at least for 3 months without any considerable divergence in potentials. The proposed membrane electrode revealed good selectivity for Al(III) ions over a wide variety of other cations. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The formation constant and stoichiometry ratio of ionophore-Al(III) complex were calculated at 25 degrees C by using segmented sandwich membrane method. It was used in non-aqueous solvents and also as indicator electrode in potentiometric determination of Al(III) ions in some real samples.
More Related Videos
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
Electrodeposition
Electrodeposition can...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...