Determination of PASHs by various analytical techniques based on gas chromatography-mass spectrometry: application to
Milagros Mezcua1, Amadeo R Fernández-Alba, Karina Boltes
1Department of Chemical Engineering and Analytical Chemistry, University of Alcalá, 28871 Madrid, Spain. mmezcua@ual.es
Abstract:
Polycyclic aromatic sulphur heterocyclic (PASH) compounds, such as dibenzothiophene (DBT) and alkylated derivatives are used as model compounds in biodesulfurization processes. The development of these processes is focused on the reduction of the concentration of sulphur in gasoline and gas-oil [D.J. Monticello, Curr. Opin. Biotechnol. 11 (2000) 540], in order to meet European Union and United States directives. The evaluation of biodesulfurization processes requires the development of adequate analytical techniques, allowing the identification of any transformation products generated. The identification of intermediates and final products permits the evaluation of the degradation process. In this work, seven sulfurated compounds and one non-sulfurated compound have been selected to develop an extraction method and to compare the sensitivity and identification capabilities of three different gas chromatography ionization modes. The selected compounds are: dibenzothiophene (DBT), 4-methyl-dibenzothiophene (4-m-DBT), 4,6-dimethyl-dibenzothiophene (4,6-dm-DBT) and 4,6 diethyl-dibenzothiophene (4,6 de-DBT), all of which can be used as model compounds in biodesulfurization processes; as well as dibenzothiophene sulfoxide (DBTO(2)), dibenzothiophene sulfone (DBTO) and 2-(2-hydroxybiphenyl)-benzenesulfinate (HBPS), which are intermediate products in biodesulfurization processes of DBT [ A. Alcon, V.E. Santos, A.B. Martín, P. Yustos, F. García-Ochoa, Biochem. Eng. J. 26 (2005) 168]. Furthermore, a non-sulfurated compound, 2-hydroxybiphenyl (2-HBP), has also been selected as it is the final product in the biodesulfurization process of DBT [A. Alcon, V.E. Santos, A.B. Martín, P. Yustos, F. García-Ochoa. Biochem. Eng. J. 26 (2005) 168]. Since, typically, biodesulfurization reactions take place in a biphasic medium, two extraction methods have been developed: a liquid-liquid extraction method for the watery phase and a solid phase extraction method for the organic phase. Recoveries of the selected compound in both media were studied. They were in the range of 80-100% for the watery and in the range of 40-60% for the organic phase, respectively. Gas chromatography coupled to mass spectrometry (GC-MS) has been employed for the identification of these selected compounds. Three different ionization modes were applied: conventional electron impact (EI); positive chemical ionization (PCI), using methane as the reagent gas; and a recently developed ionization mode known as hybrid chemical ionization (HCI), using perfluorotri-n-butylamine as the reagent gas. Limits of detection and identification capabilities have been compared between the three analytical techniques. The sensitivity of the three analytical techniques was studied and LOD between 0.05 and 1, between 0.09 and 2 and between 0.001 and 0.043 were achieved for PCI, EI and HCI, respectively. The developed method was applied in samples from a biodesulfurization process. The biodesulfurization reactions were conducted in resting cell operation mode, using Erlenmeyer flasks or an agitated tank bioreactor. The microorganism employed was Pseudomonas putida CECT 5279. The reaction was performed under controlled air flow, stirring and temperature conditions.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...