Related Experiment Video
Updated: Jul 4, 2026

Coherent anti-Stokes Raman Scattering (CARS) Microscopy Visualizes Pharmaceutical Tablets During Dissolution
Published on: July 4, 2014
Better understanding of dissolution behaviour of amorphous drugs by in situ solid-state analysis using Raman
M Savolainen1, K Kogermann, A Heinz
1Division of Pharmaceutical Technology, Faculty of Pharmacy, University of Helsinki, Helsinki, Finland. marja.savolainen@helsinki.fi
Abstract:
Amorphous drugs have a higher kinetic solubility and dissolution rate than their crystalline counterparts. However, this advantage is lost if the amorphous form converts to the stable crystalline form during the dissolution as the dissolution rate will gradually change to that of the crystalline form. The purpose of this study was to use in situ Raman spectroscopy in combination with either partial least squares discriminant analysis (PLS-DA) or partial least squares (PLS) regression analysis to monitor as well as quantify the solid-phase transitions that take place during the dissolution of two amorphous drugs, indomethacin (IMC) and carbamazepine (CBZ). The dissolution rate was higher from amorphous IMC compared to the crystalline alpha- and gamma-forms. However, the dissolution rate started to slow down during the experiment. In situ Raman analysis verified that at that time point the sample started to crystallize to the alpha-form. Amorphous CBZ instantly started to crystallize upon contact with the dissolution medium. The transition from the amorphous form to CBZ dihydrate appears to go through the anhydrate form I. Based on the PLS analysis the amount of form I formed in the sample during the dissolution affected the dissolution rate. Raman spectroscopy combined with PLS-DA was also more sensitive to the solid-state changes than X-ray powder diffraction (XRPD) and was able to detect changes in the solid-state that could not be detected with XRPD.
More Related Videos
Related Concept Videos
Factors Affecting Dissolution: Polymorphism, Amorphism and Pseudopolymorphism
Some polymorphic crystals possess lower aqueous solubility than their amorphous counterparts, leading to incomplete absorption. For instance, the oral suspension of Chloramphenicol, which...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
In Vitro Drug Dissolution: Alternative Methods
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Theories of Dissolution: Diffusion Layer Model
This process starts with a thin layer, saturated with the drug, forming at the interface between the solid and liquid. The solute then diffuses from this layer into the main solution. The Noyes-Whitney equation suggests that the rate of dissolution relies on the diffusion...
Factors Affecting Dissolution: Particle Size and Effective Surface Area