Related Experiment Video
Updated: Jul 4, 2026

A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery
Published on: May 20, 2016
FLAIR-/T1-/T2-co-registration for image-guided diagnostic and resective epilepsy surgery
Mehran Mahvash1, Roy König, Horst Urbach
1Department of Neurosurgery, University of Bonn, Bonn, Germany.
Objective:
For technical reasons, T2-weighted and fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) sequences do not allow morphological orientation with high anatomic resolution, but they may show small epileptogenic lesions. Considering the peculiarities of diagnostic and resective epilepsy surgery the present study focused on the co-registration of various magnetic resonance sequences for guided epilepsy surgery.
Methods:
Fifty patients (24 men; 26 women) aged 2 to 74 years (mean, 32 yr), in whom epileptogenic lesions were not readily identifiable on three-dimensional T1-weighted MRI scans underwent additional two-dimensional T2-weighted and FLAIR sequences before diagnostic and/or resective epilepsy surgery. FLAIR and/or T2-weighted images were co-registered to the T1-weighted data set and were displayed on the navigation station on site for guided invasive diagnostics and for resection according to an individualized resection plan. Postoperative MRI scanning was routinely performed for assessment of resection extent.
Results:
Co-registered T1- and FLAIR-/T2-images allowed for image-guided intraoperative identification of all lesions (n = 50). Control MRI scans revealed that complete resection was performed as planned before the operation in 49 patients and incomplete resection was performed in one patient. Preliminary seizure outcome with a mean follow up of 14 months (range, 7-24 mo) was assigned according to the Engel classification: Class I, 78%; Class II, 12%; Class III, 4%; Class IV, 6%.
Conclusion:
Image guidance on the basis of image fusion/co-registration of T1- and FLAIR-/T2-images allows for intraoperative identification of otherwise poorly visible lesions on standard MRI sequences in good spatial resolution. Recall of this information during surgery from the navigation system's screen assists in achieving the goal of precise electrode placement, or complete resection of the lesion as well as of the perilesional epileptogenic tissue and improves the surgeon's intraoperative orientation.