Related Experiment Video
Updated: Jul 4, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Discrepancy between simultaneous digital skin microvascular and brachial artery macrovascular post-occlusive
Matthieu Roustit1, Grant H Simmons, Jean-Philippe Baguet
1Clinical Research Center, INSERM CIC03, Grenoble University Hospital, Grenoble, France.
Objective:
Vascular impairment, a main feature of the pathogenesis of systemic sclerosis (SSc), involves both the macro- and the microvasculature. We compared and correlated simultaneously measured skin microvascular and brachial artery macrovascular post-occlusive hyperemia in 3 groups: patients with SSc, patients with primary Raynaud's phenomenon (RP), and healthy volunteers.
Methods:
Thirty-three healthy volunteers, 36 patients with primary RP, and 42 patients with SSc were enrolled. For each subject, brachial artery flow-mediated dilation (FMD) and cutaneous post-occlusive reactive hyperemia (PORH) were simultaneously recorded after 5-minute occlusion of the brachial artery. Local thermal hyperemia, nitroglycerin-mediated dilation (NMD), intima-media thickness (IMT), and pulse wave velocity (PWV) were also assessed.
Results:
Digital cutaneous peak PORH was altered in patients with primary RP and SSc compared to healthy controls, whereas FMD was not significantly different among all groups. We observed a correlation between digital peak cutaneous vascular conductance and brachial FMD in healthy controls (r = 0.49; p = 0.004), but not in patients with primary RP or SSc. Thermal hyperemia was altered only in patients with SSc. Brachial NMD, IMT, and PWV were not different among all groups.
Conclusion:
We observed a loss of the correlation between brachial FMD and digital cutaneous PORH in patients with SSc and primary RP. Microvascular function is impaired in SSc, whereas brachial artery endothelial function is normal.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests