Abstract:
A tomogram of a finger joint showing articular cartilage was generated based on X-ray dark-field imaging (XDFI) using the shift-and-add tomosynthesis algorithm. The experiment was performed at beamline 14B of the Photon Factory in Tsukuba, Japan, using synchrotron X-rays from a vertical wiggler. The incident X-ray energy was 36.0 keV. The X-ray optics for XDFI comprised two Si crystals: an asymmetric cut Si (220) monochromator-collimator and a 1.1-mm thick Si (220) Laue-case analyzer. The object was an intact cadaveric proximal interphalangeal joint fixed in formalin. Raw projection data were acquired by XDFI in a total of 41 views through an angle of 20 degrees in 0.5 degrees increments. The object and detector were synchronously rotated such that the fulcrum plane in the object and detector plane remained parallel. The X-ray dose for one piece of raw projection data was set to one-eleventh of that for one standard projection image by XDFI. Eleven views through an angle of 10 degrees in increments of 1 degrees of all 41 appropriately shifted raw projection data were added to produce arbitrary tomograms parallel to the fulcrum plane. We obtained a clear tomogram of the finger joint including the articular cartilage with the moderate artifact peculiar to tomosynthesis. Consequently, arbitrary tomograms can be obtained for the same X-ray dose as that received for one standard projection image by XDFI. The fact that an inner structure such as articular cartilage, which is invisible to conventional X-ray imaging methods, has been visualized on a tomogram with preserved refraction-enhanced contrast, is of considerable significance to clinical medicine.
More Related Videos
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
07:06Use of Micro X-ray Computed Tomography with Phosphotungstic Acid Preparation to Visualize Human Fibromuscular Tissue
Published on: September 5, 2019
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...