Related Experiment Video
Updated: Jul 3, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Isolated acute iatrogenic aortic dissection during percutaneous coronary intervention without involvement of the
Christophe A Wyss1, Jan Steffel, Thomas F Lüscher
1Division of Cardiology, University Hospital Zürich, Rämistrasse 100, CH-8091 Zürich, Switzerland. christophe.wyss@usz.ch
Insights
Aortic dissection occurred during coronary angiography due to catheter manipulation. Surgical repair involved aortic valve and ascending aorta replacement, revealing myxoid degeneration.
Area of Science:
- Cardiology
- Vascular Surgery
- Pathology
Background:
- Coronary angiography is a standard procedure for diagnosing coronary artery disease.
- Complications, though rare, can arise from invasive cardiovascular interventions.
- Acute aortic dissection is a life-threatening condition involving a tear in the aorta's inner layer.
Observation:
- A 63-year-old male developed acute aortic dissection with supracoronary entry during attempted left coronary artery intubation.
- The dissection occurred without direct involvement of the coronary arteries.
- Emergency surgery was performed, including aortic valve prosthesis implantation and replacement of the supracoronary thoracic aorta and aortic arch.
Findings:
- Histological examination revealed myxoid degeneration and disrupted elastic fiber architecture in the aorta.
- The patient exhibited no clinical features of hereditary connective tissue diseases.
- Skin biopsy excluded signs of Marfan's or Ehlers Danlos Syndrome.
Implications:
- This case highlights a rare complication of coronary angiography, emphasizing the importance of careful catheter technique.
- Myxoid degeneration without syndromic features suggests potential idiopathic aortic disease.
- Further investigation into the etiology of aortic degeneration in the absence of connective tissue disorders is warranted.
Abstract:
A 63-year-old male underwent elective coronary angiography at our institution. After three attempts to intubate the left coronary artery with an Amplatz catheter, an acute aortic dissection with a supracoronary entry occurred without involvement of the coronary arteries. In an emergency surgical procedure, an aortic valve prosthesis was implanted, and the supracoronary thoracic aorta and half of the aortic arch was replaced. Histology demonstrated myxoid degeneration and a disturbed architecture of the elastic fibers of the aorta. The patient had no features of hereditary connective tissue diseases; furthermore, a skin biopsy revealed no signs of Marfan's or Ehlers Danlos Syndrome.