Bead Based Multiplex Assay for Analysis of Tear Cytokine Profiles
Published on: October 13, 2017
Multiple cytokine analysis in human tears: an optimized procedure for cytometric bead-based assay
Martin W LaFrance1, Lucy E Kehinde, Roderick J Fullard
1School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA.
This study optimized cytometric bead-based assay (CBA) for human tear cytokines. Luminex and Bio-Rad platforms are recommended for reliable tear cytokine measurement.
Area of Science:
- Ophthalmology
- Immunology
- Biotechnology
Background:
- Cytometric bead-based assay (CBA) is a powerful tool for cytokine analysis.
- Human tear fluid is a valuable source of biomarkers for ocular surface diseases.
- Standard CBA protocols require optimization for small tear sample volumes.
Purpose of the Study:
- To compare different instruments and reagent kits for CBA of cytokines in human tears.
- To establish an optimized protocol for tear cytokine analysis using CBA.
- To evaluate the performance of CBA for measuring tear cytokines.
Main Methods:
- Two CBA instruments and reagent kits from five vendors were evaluated in parallel.
- Vendor protocols were modified to accommodate low tear volumes (1-4 µL).
- Assay precision, recovery, dilution linearity, and sample stability were assessed.
Main Results:
- Luminex and Bio-Rad platforms demonstrated optimal performance for tear CBA.
- Good dilution linearity (r > 0.80, p < 0.05) was achieved with small tear volumes.
- Tear cytokine concentrations remained stable for at least 30 minutes at room temperature.
Conclusions:
- Optimized CBA protocols enable reliable measurement of numerous cytokines in human tears.
- The established method supports cytokine analysis during sample collection periods.
- This technique facilitates biomarker discovery in ocular surface disease research.