Related Experiment Video
Updated: Jul 3, 2026

A Novel Bioreactor for High Density Cultivation of Diverse Microbial Communities
Published on: December 25, 2015
High oxygen transfer rate in a new aeration system using hollow fiber membrane
1Department of Bioscience, The Nishi-Tokyo University, Uenohara, Yamanashi 409-01, Japan.
Abstract:
A new type of bubble aeration column called a hollow fiber membrane (HFM) aeration column was proposed, which was featured in the use of hollow fiber membranes and gave a high bubble density in the column. The value of k(L)a was increased by modifying the membrane surface for making the pore size smaller. The Sauter mean diameter of bubbles (D(vs)) was 2.0 +/- 0.1 mm in the range of the superficial gas velocity from 0.02 m s(-1) to 0.065 m s(-1), while that obtained for the bubbles near the membrane was 811 mum at the superficial gas velocity of 4.0 x 10(-4) m s(-1). The difference was ascribed to the effect of coalescence of bubbles. The value of K(L)a increased in proportion to the superficial gas velocity up to 0.02 m s(-1), and was almost constant above 0.03 m s(-1). The maximum value of k(L)a, 2.5 s(-1), was higher than those of the other aeration columns reported previously. The pneumatic power consumption per unit liquid volume (P(v)) for obtaining the same k(L)a was the smallest in the HFM aeration columns. P(v), for obtaining the same interfacial area of bubbles per liquid volume, was also lower than those for other types of aeration columns. It was suggested from the measurement of bubble diameter that the larger interfacial area generated in the HFM aeration column ascribes to the larger gas holdup than the smaller D(vs).
Related Concept Videos
Bioreactor Controls-II
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Gas Exchange and Transport
Oxygen Transport in the Blood
Bioreactor Design and Operational System

